Home » Products » Molecular Diagnostics » Lab Equipments » Nucleic Acid DNA/RNA Aerosol Pollution Removal Instrument

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button

Nucleic Acid DNA/RNA Aerosol Pollution Removal Instrument

  • Clear Aerosol DNA/RNA for Bio-labs.
  • Air Sterilization & Purification.
  • Microbial Contamination Preventing.
Package:
Availability:
Quantity:
  • NC1001/NC1002

  • BioTeke

Nucleic Acid DNA/RNA Aerosol Pollution Removal Instrument


Intended Use


The Nucleic Acid DNA/RNA Aerosol Pollution Removal Instrument is used to remove aerosol DNA/RNA in the laboratory air, and also sterilize the space area where the microbial limit is required, which can directly kill bacteria, fungi, viruses, etc.


Principle

1. Hydrogen peroxide produces highly oxidizing free radicals and reactive oxygen species, which destroy the cell membranes, proteins and genetic material of microorganisms, thereby achieving the effect of sterilization and disinfection.


2. Nucleic acid remover, by continuously generating highly reactive hydroxylgroups, it non-selectively destroys the phosphodiester bonds of nucleic acids and degrades DNA/RNA.


Impact of Nucleic Acid Contamination

As a scientific research and clinical testing site, use PCR is used more frequently in molecular laboratories, and samples and amplification targets often have the same situation in multiple batches.


Nucleic acid aerosol contamination continues to accumulate in the experimental area, causing the increase of the risk of contamination and false positive frequency.


Contamination of nucleic acid aerosols resulting from the high amplification efficiency of PCR technology can cause false positives in the test results. A false positive means that the experiment is notcredible and directly causes economic losses of the laboratory. Cause the pollution of the entire PCR laboratory, and even close the laboratory.


Application Scenarios
  • Molecular biology testing laboratories.

  • Physical and chemical laboratories.

  • Hospital, CDCs, GMP workshop, Customs.

  • Other medical institutions, etc.


Parameters


Model NC1001/NC1002
Sterilization Method Spray(Ultrasonic atomization)
Disinfectant Hydrogen peroxide(8%-35% concentration)
Pollution Removers Bioteke nueleic acid removers
Applicable Space Volume 100-300 m³
Pollution Control Bulit in HEPA filters
Operation Touch-screen and remote control
Spray Mist Diameter ≤5um
Warrantly 1 year
Size 560*560*1200mm
Weight 60KG
Power 220V AC, 50~60Hz
Certification
Test report, Safety evaluation report, CE


Downloads

Nucleic acid aerosol pollution removal instrument brochure


Nucleic acid aerosol pollution removal instrument user instruction 



How To Order
  • Via the Contact Bioteke page, fill in the form with all the necessary details and we will email you back asap.

  • Or contact Bioteke Sales Team via Phone/Whatsapp +86-133-5792-7939.

  • E-mail: zr@bioteke.cn





Previous: 
Next: 
No.90 Huiming Road, Huishan, Wuxi City, Jiangsu 214000, China
zr@bioteke.cn
86-510-8332-3992
QUICK LINKS
PRODUCT CENTER
Copyright BioTeke Corporation(wuxi) Co.,Ltd  |   苏ICP备18042459号-1