5 In 1 Multiple Respiratory Multipathogen Antigen Test Kit

  • In vitro diagnostic device.
  • Anterior nasal swab specimen.
  • CE mark, ISO13485 certified.
  • For professional use.
Test Kit:
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button
  • ICA2114-7

  • BioTeke



5 In 1 Multiple Respiratory Multipathogen Antigen Test Kit

FOR PROFESSIONAL USE

Intended Use

       The kit uses immunochromatography and double-antibody sandwich methods for in vitro qualitative detection of SARS-CoV-2(COVID-19), influenza A(Flu A), influenza B(Flu B), respiratory syncytial virus(RSV), and respiratory adenovirus(ADV) antigens in human anterior nasal swab samples.

Product Description


  • Commercial name: Multiple Respiratory Multipathogen Antigen Test Kit

  • Brand: Bioteke

  • Detection item: SARS-CoV-2, Flu A, Flu B, RSV, ADV

  • Specimen: Anterior nasal swab

  • Shelf life: 24 months

  • Storage condition: 2~30℃

  • Certification: CE, ISO13485

  • Scenario: For professional use

respiratory panel test

Click here to watch the video.


Advantages

1). 1 step, up to 5 test results.

2). Only one drop is needed, no need to repeat the addition.

3). Get accurate test results within 15 minutes without waiting for a long time.

4). Painless testing.

5). Multi-color display of test results, easy to interpret.

6). No need for professional equipment, detection anytime, anywhere.



5 in 1 rapid antigen test kit

respiratory antigen rapid test

Package
1 Test/Kit ; 600 Tests/Carton
20 Tests/Kit ; 800 Tests/Carton
Box size: 16.2×6.6×1.5cm Box size: 24×16.6×6.5cm
Carton size: 66×40×42cm Carton size: 68×49×35cm


[Results Interpretation]

Note: Please read the results within 15-20 minutes after the test. Results read after 30 minutes will be invalid.


[Positive]

SARS-CoV-2 positive:Two  coloured lines appear  in  the  COVID-19/Flu A/Flu B test  window.A  dark blue/purple Iine is in the(C) section and a red line is in the (COVID-19) section. 

Influenza A (Flu A) positive:Two coloured lines appear in the COVID-19/Flu A/Flu B test window.A dark blue/purple Iine is in the(C) section and a blue line is in the (Flu A) section.

Influenza B (Flu B) positive:Two coloured lines appear in the COVID-19/Flu A/Flu B test window.A dark blue/purple Iine is in the(C) section and a blue line is in the (Flu B) section.

Adenovirus (ADV) positve:Two coloured lines appear in the ADV/RSV test window.A dark blue/purple Iine is in the(C) section and a red line is in the (ADV) section.

Syncytial virus (RSV)  positive:Two coloured lines appear in the ADV/RSV test window.A dark blue/purple Iine is in the(C) section and a blue line is in the (RSV) section.

Multiple positive:Two coloured (C) lines appear in two separate window.If the other line appears,the corresponding pathogen is positive.

positive


[Negative]

In the SARS-CoV-2/Influenza A virus/Influenza B virus/Respiratory syncytialvirus/Adenovirus detection window,two dark blue/purple lines appear in the (C) section and no line appears in the detection area (COVID-19/Flu A/Fu B/ADV/RSV).It indicates that SARS-CoV-2,Influenza A virus,Influenza B virus,Respiratorysyncytial virus or Adenovirus was not detected in the sample.However,a negative result does not exclude the absence of SARS-CoV-2,influenza A virus,influenza B virus,respiratory syncytial virus,Adenovirus infection and should not be used as the sole basis for treatment or patient management decisions.

Negative results should be considered in the context of the individuals recent exposure history,medical history and the presence of clinical signs and symptoms consistent with SARS-CoV-2,influenza A virus,Influenza B virus,Respiratory syncytial virus and adenovirus,and confirmed by nucleic acid testing as necessary for patient management.

negative


[Invalid]

If any of the control (C) lines do not appear,the test is considered invalid.

An invalid test result means that your test has encountered an error and the results cannot be interpreted.You will need to retest using a new test card.

invalid



[Related Product]

bioteke 5 in 1 test

Bioteke 5 in 1(Self-test)

bioteke 6 in 1

Bioteke 6 in 1

bioteke 8 in 1

Bioteke 8 in 1

bioteke 10 in 1

Bioteke 10 in 1

Back to home.


Previous: 
Next: 
QUICK LINKS
PRODUCT CENTER
CONTACT US
Placeholder Image

   Telephone: +86-510-8332 3992

Copyright BioTeke Corporation(wuxi) Co.,Ltd  |   苏ICP备18042459号-1